Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
ACS Appl Nano Mater ; 5(12): 17503-17507, 2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: covidwho-2185499

RESUMEN

In this work, we report a 5-min magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface-functionalized magnetic nanoparticles are incubated with target analytes at 37 °C with agitation for 3 min, and the MPS reading is then taken at the fifth minute. We prove the feasibility of 5 min ultrafast detection of SARS-CoV-2 spike protein with a detection limit below 5 nM (0.2 pmol). Our proposed 5-min bioassay strategy may be applied to reduce the assay time for other liquid-phase, volumetric biosensors such as NMR, quantum dots, fluorescent biosensors, etc.

2.
BMC Ophthalmol ; 22(1): 518, 2022 Dec 30.
Artículo en Inglés | MEDLINE | ID: covidwho-2196117

RESUMEN

BACKGROUND: The purpose of this study was: [1] to evaluate the infectivity of two SARS-CoV-2 lineage A variants on human ocular tissues in vitro, and [2] to evaluate the stability of SARS-CoV-2 lineage A variants in corneal preservation medium. METHODS: Primary cultures of donor corneal, conjunctival, and limbal epithelium were inoculated with two lineage A, GISAID clade S isolates of SARS-CoV-2 (Hong Kong/VM20001061/2020, USA-WA1/2020), to evaluate the susceptibility of the ocular tissue to infection. Flat-mounted Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) grafts were inoculated with SARS-CoV-2 to evaluate the susceptibility of the endothelium to infection. All inoculated samples were immunostained for SARS-CoV-2 nucleocapsid (N)-protein expression to confirm positive infection. SARS-CoV-2 Hong Kong was then inoculated into cornea preservation media (Life4°C, Numedis, Inc.). Inoculated media was stored at 4oC for 14 days and assayed over time for changes in infectious viral titers. RESULTS: Corneal, conjunctival, and limbal epithelial cells all demonstrated susceptibility to infection by SARS-CoV-2 lineage A variants. Conjunctiva demonstrated the highest infection rate (78% of samples infected [14/18]); however, infection rates did not differ statistically between cell types and viral isolates. After inoculation, 40% (4/10) of DSAEK grafts had active infection in the endothelium. SARS-CoV-2 lineage A demonstrated < 1 log decline in viral titers out to 14 days in corneal preservation media. CONCLUSIONS: SARS-CoV-2 lineage A variants can infect corneal, limbal, and conjunctival epithelium, as well as corneal endothelium. There was no statistical difference in infectivity between different lineage A variants. SARS-CoV-2 lineage A can survive and remain infectious in corneal preservation media out to 14 days in cold storage.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Córnea/cirugía , Endotelio Corneal/trasplante , Conjuntiva
3.
Viruses ; 13(12)2021 12 14.
Artículo en Inglés | MEDLINE | ID: covidwho-1572668

RESUMEN

Broad-spectrum antiviral therapies hold promise as a first-line defense against emerging viruses by blunting illness severity and spread until vaccines and virus-specific antivirals are developed. The nucleobase favipiravir, often discussed as a broad-spectrum inhibitor, was not effective in recent clinical trials involving patients infected with Ebola virus or SARS-CoV-2. A drawback of favipiravir use is its rapid clearance before conversion to its active nucleoside-5'-triphosphate form. In this work, we report a synergistic reduction of flavivirus (dengue, Zika), orthomyxovirus (influenza A), and coronavirus (HCoV-OC43 and SARS-CoV-2) replication when the nucleobases favipiravir or T-1105 were combined with the antimetabolite 6-methylmercaptopurine riboside (6MMPr). The 6MMPr/T-1105 combination increased the C-U and G-A mutation frequency compared to treatment with T-1105 or 6MMPr alone. A further analysis revealed that the 6MMPr/T-1105 co-treatment reduced cellular purine nucleotide triphosphate synthesis and increased conversion of the antiviral nucleobase to its nucleoside-5'-monophosphate, -diphosphate, and -triphosphate forms. The 6MMPr co-treatment specifically increased production of the active antiviral form of the nucleobases (but not corresponding nucleosides) while also reducing levels of competing cellular NTPs to produce the synergistic effect. This in-depth work establishes a foundation for development of small molecules as possible co-treatments with nucleobases like favipiravir in response to emerging RNA virus infections.


Asunto(s)
Antimetabolitos/farmacología , Antivirales/farmacología , Virus ARN/efectos de los fármacos , Adenosina Trifosfato/metabolismo , Amidas/farmacología , Animales , Línea Celular , Sinergismo Farmacológico , Guanosina Trifosfato/metabolismo , Humanos , Metiltioinosina/farmacología , Mutación/efectos de los fármacos , Fosforribosil Pirofosfato/metabolismo , Pirazinas/farmacología , Virus ARN/clasificación , Virus ARN/genética , ARN Viral/efectos de los fármacos , ARN Viral/genética , Replicación Viral/efectos de los fármacos
4.
ACS Appl Mater Interfaces ; 13(37): 44136-44146, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: covidwho-1402018

RESUMEN

With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high-accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround time that may worsen the disease surveillance and pandemic control. In sight of this situation, a rapid, one-step, easy-to-use, and high-accuracy diagnostic platform will be valuable for future epidemic control, especially for regions with scarce medical resources. Herein, we report a magnetic particle spectroscopy (MPS) platform for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) biomarkers: spike and nucleocapsid proteins. This technique monitors the dynamic magnetic responses of magnetic nanoparticles (MNPs) and uses their higher harmonics as a measure of the nanoparticles' binding states. By anchoring polyclonal antibodies (pAbs) onto MNP surfaces, these nanoparticles function as nanoprobes to specifically bind to target analytes (SARS-CoV-2 spike and nucleocapsid proteins in this work) and form nanoparticle clusters. This binding event causes detectable changes in higher harmonics and allows for quantitative and qualitative detection of target analytes in the liquid phase. We have achieved detection limits of 1.56 nM (equivalent to 125 fmole) and 12.5 nM (equivalent to 1 pmole) for detecting SARS-CoV-2 spike and nucleocapsid proteins, respectively. This MPS platform combined with the one-step, wash-free, nanoparticle clustering-based assay method is intrinsically versatile and allows for the detection of a variety of other disease biomarkers by simply changing the surface functional groups on MNPs.


Asunto(s)
COVID-19/virología , Nanopartículas/química , Proteínas de la Nucleocápside/química , SARS-CoV-2/química , Análisis Espectral/métodos , Glicoproteína de la Espiga del Coronavirus/química , Análisis por Conglomerados , Humanos
5.
J Phys Chem C Nanomater Interfaces ; 125(31): 17221-17231, 2021 Aug 12.
Artículo en Inglés | MEDLINE | ID: covidwho-1371585

RESUMEN

In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in the liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxins, nucleic acids, and so forth. Herein, we report a modified version of the MPS platform with the addition of a one-stage lock-in design to remove the feedthrough signals induced by external driving magnetic fields, thus capturing only MNP responses for improved system sensitivity. This one-stage lock-in MPS system is able to detect as low as 781 ng multi-core Nanomag50 iron oxide MNPs (micromod Partikeltechnologie GmbH) and 78 ng single-core SHB30 iron oxide MNPs (Ocean NanoTech). We first demonstrated the performance of this MPS system for bioassay-related applications. Using the SARS-CoV-2 spike protein as a model, we have achieved a detection limit of 125 nM (equal to 5 pmole) for detecting spike protein molecules in the liquid phase. In addition, using a streptavidin-biotin binding system as a proof-of-concept, we show that these single-core SHB30 MNPs can be used for Brownian relaxation-based bioassays while the multi-core Nanomag50 cannot be used. The effects of MNP amount on the concentration-dependent response profiles for detecting streptavidin were also investigated. Results show that by using a lower concentration/ amount of MNPs, concentration-response curves shift to a lower concentration/amount of target analytes. This lower concentration-response indicates the possibility of improved bioassay sensitivities by using lower amounts of MNPs.

6.
ACS Appl Mater Interfaces ; 13(7): 7966-7976, 2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: covidwho-1075146

RESUMEN

Nowadays, there is an increasing demand for more accessible routine diagnostics for patients with respect to high accuracy, ease of use, and low cost. However, the quantitative and high accuracy bioassays in large hospitals and laboratories usually require trained technicians and equipment that is both bulky and expensive. In addition, the multistep bioassays and long turnaround time could severely affect the disease surveillance and control especially in pandemics such as influenza and COVID-19. In view of this, a portable, quantitative bioassay device will be valuable in regions with scarce medical resources and help relieve burden on local healthcare systems. Herein, we introduce the MagiCoil diagnostic device, an inexpensive, portable, quantitative, and rapid bioassay platform based on the magnetic particle spectrometer (MPS) technique. MPS detects the dynamic magnetic responses of magnetic nanoparticles (MNPs) and uses the harmonics from oscillating MNPs as metrics for sensitive and quantitative bioassays. This device does not require trained technicians to operate and employs a fully automatic, one-step, and wash-free assay with a user friendly smartphone interface. Using a streptavidin-biotin binding system as a model, we show that the detection limit of the current portable device for streptavidin is 64 nM (equal to 5.12 pmole). In addition, this MPS technique is very versatile and allows for the detection of different diseases just by changing the surface modifications on MNPs. Although MPS-based bioassays show high sensitivities as reported in many literatures, at the current stage, this portable device faces insufficient sensitivity and needs further improvements. It is foreseen that this kind of portable device can transform the multistep, laboratory-based bioassays to one-step field testing in nonclinical settings such as schools, homes, offices, etc.


Asunto(s)
Bioensayo , Nanopartículas de Magnetita/química , Teléfono Inteligente , Estreptavidina/análisis , Bioensayo/instrumentación , COVID-19/diagnóstico , Humanos , Hidrodinámica , Gripe Humana/diagnóstico , Fenómenos Magnéticos , Tamaño de la Partícula , Propiedades de Superficie
7.
J Immunol ; 206(5): 931-935, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1028951

RESUMEN

The magnitude of SARS-CoV-2-specific T cell responses correlates inversely with human disease severity, suggesting T cell involvement in primary control. Whereas many COVID-19 vaccines focus on establishing humoral immunity to viral spike protein, vaccine-elicited T cell immunity may bolster durable protection or cross-reactivity with viral variants. To better enable mechanistic and vaccination studies in mice, we identified a dominant CD8 T cell SARS-CoV-2 nucleoprotein epitope. Infection of human ACE2 transgenic mice with SARS-CoV-2 elicited robust responses to H2-Db/N219-227, and 40% of HLA-A*02+ COVID-19 PBMC samples isolated from hospitalized patients responded to this peptide in culture. In mice, i.m. prime-boost nucleoprotein vaccination with heterologous vectors favored systemic CD8 T cell responses, whereas intranasal boosting favored respiratory immunity. In contrast, a single i.v. immunization with recombinant adenovirus established robust CD8 T cell memory both systemically and in the respiratory mucosa.


Asunto(s)
Linfocitos T CD8-positivos/inmunología , Vacunas contra la COVID-19/inmunología , COVID-19/inmunología , COVID-19/prevención & control , Epítopos de Linfocito T/inmunología , SARS-CoV-2/inmunología , Vacunación/métodos , Enzima Convertidora de Angiotensina 2/genética , Enzima Convertidora de Angiotensina 2/metabolismo , Animales , COVID-19/virología , Células Cultivadas , Proteínas de la Nucleocápside de Coronavirus/inmunología , Modelos Animales de Enfermedad , Femenino , Vectores Genéticos/inmunología , Antígeno HLA-A2/inmunología , Humanos , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos
8.
PLoS One ; 15(4): e0231723, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-827309

RESUMEN

Understanding the immune responses against Porcine epidemic diarrhea virus (PEDV) is important to prevent infection and to design control strategies. We evaluated both systemic and mucosal immune responses to PEDV in pigs and assessed if prior exposure to virus protects against re-infection. Three-week-old pigs were infected with PEDV and immune response in blood, intestine, and mesenteric lymph node (MLN) was evaluated. At 30 dpi, virus exposed pigs were challenged with a field isolate of PEDV and immune response at 5 d post challenge was evaluated. We found that PEDV RNA persists in the intestine even after fecal shedding of the virus was stopped at 28 dpi and pigs previously exposed to PEDV are protected from virus shedding after re-infection. PEDV infection induced both humoral and cell mediated immune response with an increase in PEDV specific IgA and IgG antibodies in intestine and serum. Flow cytometry analysis showed a significantly higher frequency of B cells and lower frequency of T cells at 4 dpi. The frequency of CD4/CD8 double positive (DP) memory T cells was significantly increased in the MLN of challenged animals. These studies may provide further insights into understanding the mucosal immune response to PEDV and its role in protection against disease.


Asunto(s)
Anticuerpos Antivirales/análisis , Infecciones por Coronavirus/inmunología , Diarrea/inmunología , Virus de la Diarrea Epidémica Porcina/inmunología , Animales , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/metabolismo , Linfocitos B/inmunología , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/veterinaria , Infecciones por Coronavirus/virología , Diarrea/sangre , Diarrea/veterinaria , Diarrea/virología , Resistencia a la Enfermedad/inmunología , Heces/microbiología , Inmunidad Celular , Inmunidad Humoral , Inmunidad Mucosa , Inmunoglobulina A/análisis , Inmunoglobulina A/inmunología , Inmunoglobulina A/metabolismo , Inmunoglobulina G/análisis , Inmunoglobulina G/inmunología , Inmunoglobulina G/metabolismo , Mucosa Intestinal/inmunología , Mucosa Intestinal/metabolismo , Virus de la Diarrea Epidémica Porcina/genética , Virus de la Diarrea Epidémica Porcina/aislamiento & purificación , ARN Viral/aislamiento & purificación , Porcinos , Linfocitos T/inmunología , Esparcimiento de Virus
9.
2020/09/22;
No convencional en Inglés | 2020/09/22 | ID: covidwho-779920

RESUMEN

The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), is a threat to the global healthcare system and economic security. As of July 2020, no specific drugs or vaccines are yet available for COVID-19, fast and accurate diagnosis for SARS-CoV-2 is essential in slowing down the spread of COVID-19 and for efficient implementation of control and containment strategies. Magnetic nanosensor is a novel and emerging topic representing the frontiers of current biosensing and magnetics areas. The past decade has seen rapid growth in applying magnetic tools for biological and biomedical applications. Recent advances in magnetic nanomaterials and nanotechnologies have transformed current diagnostic methods to nanoscale and pushed the detection limit to early stage disease diagnosis. Herein, this review covers the literatures of magnetic nanosensors for virus and pathogen detections, before COVID-19. We reviewed the popular magnetic nanosensors including magnetoresistance (MR) sensors, magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR). Magnetic Point-of-Care (POC) diagnostic kits are also reviewed aiming at developing plug-and-play diagnostics to manage the SARS-CoV-2 outbreak as well as preventing future epidemics. In addition, other platforms that use magnetic nanomaterials as auxiliary tools for enhanced pathogen and virus detections are also covered. The goal of this review is to inform the researchers of diagnostic and surveillance platforms for SARS-CoV-2 and their performances.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA